Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4256 INPUT AND OUTPUT MATCH (Traveling-wave tubes) 1. Purpose. To define methods of measuring input and output hot and cold match. 2. Definitions. 2.2 Hot input (or output) match. The match of the input (or output) with operating voltages and drive applied as specified on the TSS. 2.1 Cold input (or output) match. The match of the input (or output) in the absence of operating voltages. 3. Introduction. Hot and cold input and output match shall be measured using a continuous frequency variation or a series of discrete frequencies between frequency limits specified under test conditions.
Slotted line techniques may be substituted for the other techniques when greater measurement accuracy of VSWR at discrete frequencies is required. Peak power ratios shall be used to establish hot-input match and hot-output match where the duty factor is other than continuous in the tube. In no case shall specified operating conditions be such as to require match measurements in non-linear regions. 4. Test methods. 4.1 Method A (reflectometer method). 4.1.1 Test circuit. FIGURE 4256-1. Reflectometer method. METHOD 4256 19 April 1968 4256-1