Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 6. Precautions. 6.1 The signal source shall be of high enough level and the attenuators shall be of sufficient value to cover the range of the tube. 6.2 Care shall be taken to prevent leakage from all rf cables and switches and connectors, including all video, dc, and collector leads. 6.3 Care shall be taken to set the indicated signal level sufficiently above the noise level in order to reduce errors. 6.4 In the case of hot-backward loss; if the TUT is operating in an unstable or nearly unstable condition, erroneous results may be obtained. This shall be taken into account to obtain meaningful results.

METHOD 4257 19 April 1968 4257-2