Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4261 SPURIOUS OUTPUT OR STABILITY (Microwave amplifier tubes) 1. Purpose. The purpose of this test is to measure the stability of a microwave amplifier by varying the load conditions without rf drive and measuring power output variations. 2.1 Test circuit. 2. Method A (broadband spurious). This is used to measure the broadband power emanating from the rf terminals of the TUT. FIGURE 4261-1. Spurious output or stability method. 2.2 Procedure.

With the TUT inserted in the circuit on figure 4261-1, with VSWR as specified, the phase of the standing-wave introducer is adjusted until a maximum power indication is obtained. The power is then measured. The bandpass filter shall have a specified bandwidth. 2.3 Precautions. 2.3.1 Under some conditions, tubes operating into a mismatch may produce out-of-band oscillations resulting in lower than normal spurious power output readings. 3. Method B (narrow-band). This is used to measure the narrow-band power emanating from the rf terminals of the TUT. 3.1 Test circuit. Replace the bandpass filter of figure 4261-1 with a tunable narrow-band filter of specified bandwidth. 3.2 Procedure.

With the TUT inserted in the circuit shown on figure 4261-1, the frequency band of the TUT shall be searched by tuning the narrow-band filter to each peak of power. The phase of the standing-wave introducer is adjusted for maximum power indication. The power is then measured. 3.3 Precautions. 3.3.1 The combination of tunable narrow-band filter and power measuring device shall have adequate sensitivity. 3.3.2 A sufficient number of standing-wave introducer positions shall be used to insure that no peaks are missed. METHOD 4261 19 April 1968 4261-1