Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4270 HEATER-CATHODE LEAKAGE (Microwave tubes) 1. Purpose. The purpose of this test is to measure the leakage current across the insulation used to isolate the heater from the cathode. This test is not applicable for tubes where the heater is tied internally to the cathode lead of the tube. 2. Procedure. Ground one of the heater leads. All other tube leads except the cathode lead shall be tied together and connected to a separate ground. Apply rated heater voltage only. Apply the TSS dc test voltage between the grounded heater lead and the cathode lead.
A protective resistor, whose value in ohms is not more than 1,000 times the H-K voltage, shall be used in series with the current meter. Measure the dc current from cathode to ground for the TSS polarities of the cathode to heater voltage. 3. Precaution. The measurement circuit shall be metered so that the only leakage current measured is that from heater to cathode. METHOD 4270 19 April 1968 4270-1