Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4279 REVERSE DIRECTED POWER 1. Purpose. To determine the amount of reverse directed power appearing at the driving terminals of an amplifier when a specified mismatch is placed at the output. 2. Equipment. As required to measure power and gain, but in addition a four port circulator to separate the reverse directed power. See figure 4279-1. 3. Procedure. With the tube operating under the specified conditions, and using the circuit shown on figure 4279-1, or equivalent, the phase of the specified VSWR shall be adjusted for maximum power on the power indicator in branch 3.
The reverse directed power is the sum of the power measured in branch 3 and the calculated power lost due to the circulator insertion loss between 2 and 3. FIGURE 4279-1. Reverse directed power measuring circuit. METHOD 4279 4279-1 19 April 1968