Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4318 JITTER MEASUREMENTS 1. Pulse-to-pulse jitter. The values of time, frequency, and amplitude for a series of power pulses generated by a microwave oscillator are not exactly identical but rather are distributed about a mean value. The pulse-to-pulse jitter shall be defined as the width of such a distribution of time, frequency, or amplitude and shall be expressed as an rms quantity. The rms pulse-to-pulse value may be computed from cumulative distribution data or by individual analysis of successive pulse pairs providing a sufficient quantity of data is taken to satisfy statistical computations.
1.1 Time jitter. Time jitter shall be measured at approximately the 3 dB power point (50 percent voltage point) shown on figure 4318-1 of the detected rf pulse. It shall represent that relative variation in starting time referenced from the leading edge of the voltage pulse as specifed on the TSS or equivalent. FIGURE 4318-1. Detected rf pulse. 1.2 Amplitude jitter. Amplitude jitter shall be measured at the top of the detected rf pulse at the point in time of maximum jitter within the usable portion of the pulse or as specified on the TSS (see figure 4318-2).
In cases where amplitude jitter in the test modulator causes an increase in oscillator jitter, that amount of jitter which is over and above the true amplitude jitter of the TUT may be deducted. FIGURE 4318-2. Detected rf pulse amplitude jitter. METHOD 4318 4318-1 19 April 1968