Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4401B IGNITOR IGNITION TIME 1. Purpose. To measure the period of time taken for the tube to ignite after application of ignitor voltage. 2. Equipment. The test circuit shown on figure 4401-1, or an equivalent circuit, shall be used for making this test. The counting circuit, which consists of a neon bulb, a 2 F capacitor, two fixed resistors (3 Meg and 5 Meg), and a 5 Meg potentiometer, may be omitted if an equally accurate alternate method of measuring time is used. The TSS shall specify the open circuit voltage, and the total series resistance (R 1 ). FIGURE 4401-1. Ignitor igniting-time circuit. 3. Procedure.

The tube shall be tested in the specified circuit and the time between voltage application and ignition shall be measured. METHOD 4401B 25 March 1970 4401-1