Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 FIGURE 4452-2. Typical power measuring circuit. 2.2.1 When using an oscilloscope with auxiliary equipment for measuring peak power levels, it is necessary to calibrate the oscilloscope by comparison with some other power measuring device. This may be done by connecting a signal generator klystron circuit like the one shown on figure 4452-3 to the crossguide coupler of figure 4452-2. FIGURE 4452-3. Typical calibration circuit. 2.2.2 The calibration of the oscilloscope may be performed separately or the calibration circuit may be connected into the leakage power measuring circuit permanently.
2.3.1 The foregoing sections show the important basic and branch circuits for measuring leakage power, and it is possible to combine these circuits in several different ways. The following circuits show typical arrangements of equipment for making leakage power measurements on different classes of tubes. 2.3 Detailed test circuits. 2.3.2 Branched duplexer tubes. 2.3.2.1 A circuit in which the basic circuit of figure 4452-1(a) is combined with a thermistor and a power meter (No. 1) is shown on figure 4452-4. A directional coupler in the main line with another thermistor and power meter (No. 2) makes provision for monitoring the input power to the TUT.
The addition of the monitoring circuit is optional. METHOD 4452A 18 August 1970 4452-2