Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 3. Procedure. The tube shall be mounted as shown in the appropriate circuit. With the generator set to the reference frequency, the VSWR immediately before the single tube, or the VSWR in the antenna port in the dual tube circuit, shall be measured. 4. Precautions. The matched terminations used in the test circuits shall have a VSWR of less than 1.05 so as not to affect the measured VSWR value. The 3 dB hybrid couplers used shall have a VSWR of less than 1.10, shall split the power evenly to within 0.25 dB, and shall have a minimum isolation of 25 dB. METHOD 4473 19 April 1968 4473-2