Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4475 (OBSOLESCENT) INTRINSIC Q (TR tubes) 1. High-Q external cavity. The tube shall be mounted in the specified cavity and placed in a circuit between a matched generator and detector. The signal generator shall be tuned to resonance, as indicated by a pronounced peak of the output indicator, and the resonant wavelength ( o) and relative value of the power transmitted to the detector (Pd) shall be recorded.

The frequency of the signal generator shall then be decreased from resonance until the transmitted power falls to one-half its original value, and the corresponding wavelength shall be measured and recorded as 1. The frequency shall then be increased above the resonant value to the half-power point and this wavelength recorded as 2. The power available at the detector (Pa) is determined by removing the tube and associated cavity from the circuit. The intrinsic Q of the tube and cavity shall be computed from the following equation: ) 1() 2 1 ( 0 T Qo Where: T = Pa Pd 0 = Wavelength at resonance. 1 = Wavelength at lower half-power point. 2 = Wavelength at higher half-power point.

This equation assumes that the input- and output-coupling devices are identical. The coupling devices may be checked for equality by measuring the VSWR with the cavity reversed so that the former output coupling device is used as the input. If the VSWR measured with the cavity in its initial position is denoted as r1, and the VSWR with the cavity reversed is r2, r1, and r2 will be equal if the coupling devices are identical. If r1 and r2 are not equal, the expression for Qo becomes: 1 2 1 2 1 2 1 1 2 1 r r r r r r o Qo 2. Intrinsic Q (relative).

The tube shall be tested on a relative basis under the conditions specified in 1 above, by comparing the reading of the output indicator at resonance with the reading for a tube whose intrinsic Q is known. The test cavity shall be isolated from the oscillator by at least 10-dB attenuation. The test equipment shall be calibrated at intervals, not to exceed 30 days, by means of tubes that have passed the intrinsic Q measurement specified in 1 above. METHOD 4475 19 April 1968 4475-1