Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4478 (OBSOLESCENT) HIGH-LEVEL PROTECTION (Gas-switching tubes) The tube shall be mounted in the cavity specified on the TSS and placed in a transmission circuit between a matched generator and detector. The power level at the input shall be sufficient to fire the rf gap of the tube, and to insure that the measurement is being made on the flat part of the power in the gap versus leakage-power curve. If the main discharge gap does not fire, it shall be caused to fire by a short application of the ignitor voltage.

The tube shall be tested on a relative basis by comparing the reading of the output meter when the gap is fired, to the reading of a standard tube when its gap is fired. The output indication of the tube shall be less than that of a standard tube. METHOD 4478 4478-1 19 April 1968