Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5236 ZERO-BIAS ANODE CURRENT (Magnetic deflection) (Cathode-ray tubes) 1. At the electrode voltages specified, the zero-bias anode current shall be measured, and shall be not less than the values specified in table 5236-I for tubes having the corresponding values of cutoff. TABLE 5236-I. Grid No. 1 cutoff voltage versus minimum zero-bias current. METHOD 5236 19 April 1968 5236-1 Grid No. 1 spot cutoff voltage Minimum zero-bias current A dc Grid No.
1 spot cutoff voltage Minimum zero-bias current A dc 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 111 123 135 149 162 176 190 205 219 235 250 270 285 300 310 335 360 377 394 419 431 449 468 487 507 527 547 567 587 607 628 650 670 692 713 735 758 780 802 825 850 872 895 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 918 943 966 991 1015 1040 1065 1090 1115 1142 1165 1192 1217 1242 1271 1296 1322 1350 1378 1405 1431 1460 1486 1515 1543 1572 1600 1629 1658 1687 1716 1746 1775 1804 1834 1864 1894 1924 1955 1986 2016 2047 2079