Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5407 ELECTRODE LEAKAGE (Cathode-ray charge storage tubes) 1. Heater-cathode leakage. In testing tubes having unipotential cathodes not connected to the heater within the tube, rated heater voltage shall be applied to the heater terminals and the instantaneous potential of any part of the heater shall be maintained at not less than 125 volts with respect to the cathode. The heater-cathode leakage current shall not exceed 10 A dc. 2. Interelectrode leakage. With the control grid biased to cutoff, the leakage between the specific electrode and all other electrodes shall not exceed the limit(s) specified.

METHOD 5407 19 April 1968 5407-1