Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5415 WRITING RESPONSE, STATIC, VISUAL OUTPUT (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is the measurement of the luminance that can be achieved by writing a single field at a specified grid drive level and at a specified scanning speed. 2. Equipment. a. A photometer shall be used to measure the luminance of the TUT over a circular area 10 5 mm (approximately .4 .2 inch) in diameter. b. A deflection system shall produce a raster on the TUT with linear sawtooth deflections in orthogonal directions. The raster size and line density shall be adjustable.

The capability to change raster scan directions by 90 shall be provided. 3. Procedure. a. Operating conditions shall be as specified in the TSS. b. Without simultaneously erasing, write all of the area specified in the TSS to saturation level. c. Stop writing. Using the erase procedure specified in the TSS for this test, erase until the last portion of the specified area has just been erased. d. The tube shall be consecutively written with a single field, viewed, and erased with the lines spaced progressively closer until the individually written lines in the raster first merge into a uniform brightness. e. Once the first merged condition is obtained, measure and record raster height.

Change the raster scan by 90 . The raster width shall be maintained equal when the raster direction is changed. Repeat 3d and adjust focus, if necessary, until raster heights in the two orthogonal directions are within 10 percent of one another. Consecutively erase and write again. Immediately measure the luminance of the specified area. NOTE: For the purpose of this test, raster height shall be measured in a direction perpendicular to that of the line scan. f. The static writing response shall be measured at the grid drive, the scanning speed, and at the faceplate location(s) specified in the TSS. g.

The static writing response shall be stated in terms of measured luminance at given grid drive and scanning speed. Static writing response = Bsw, a function (V,S). Where: Bsw = luminance of specified area (foot lamberts) V = grid drive (volts) S = scanning speed (inches/second) Alternatively, static writing response may be stated as a percentage, Rsw (V, S) = %. 100 ) , ( x Bsat S V Bsw Bsw (V,S) is the luminance change between the written and the erased condition and Bsat is the saturated luminance. METHOD 5415 12 December 1972 5415-1