Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 4. Procedure. a. Operating voltages and conditions shall be within the limits specified in the TSS. b. The size and position of the writing and reading rasters shall be adjusted such that both rasters are squares inscribed in the SSRD. c. Adjust reading and erasing conditions and writing-gun drive to achieve a stabilized writing and erasing cycle whereby: (1) The slowest erasing portion of the reading raster area is just erased immediately prior to being rewritten. (2) The written scan lines in the fastest writing area are written to 90 percent of saturation level. NOTE:

The stability of the writing and erasing cycle shall be verified by observation over a period of 2 minutes, or as specified in the TSS. d. Measure writing-gun drive. e. Locate the slowest writing area, and using the oscilloscope line selector, measure the peak signal in that area immediately after writing. f. If a separate erasing cycle is used, measure the cathode current during erase or the erasing-gun drive, as specified in the TSS. 5. TSS requirements. a. In addition to the operating conditions for the TUT, the TSS shall specify the following: (1) Maximum writing-gun drive. (2) Minimum reading-output signal immediately after writing.

(3) Maximum cathode current or maximum gun drive for a separate erasing cycle. b. If values other than those specified in this test method are required, the TSS shall specify: (1) Writing scan rates. (2) Erasing rate. (3) Stability observation time. METHOD 5418 12 December 1972 5418-2