Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5420 GRAY SCALE RESPONSE, ELECTRICAL OUTPUT (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to determine the response of the TUT to a gray scale test pattern input. The response is determined by examining the output signal resulting from writing with a linear staircase voltage input signal. 2. Equipment. a. A deflection system shall produce television-type writing and reading rasters in the TUT at television rates (approximately 50 to 60 Hz). b.
The TUT shall be monitored on a CRT with a raster scan synchronized to the reading raster, and on an oscilloscope with provision for selecting the video output from any line of the reading raster. c. The output-signal amplifier shall be linear, compensated for the output impedance of the TUT and have a frequency response that is flat within 1 dB over a bandwidth wide enough to insure accurate display of the gray scale capabilities of the TUT. d. A video signal generator shall produce a gray scale test pattern from a linear staircase voltage synchronized to the writing raster.
The staircase voltage waveform at the storage tube input shall have equal amplitude steps with overshoots of 1.0 percent maximum, undershoots of 1.0 percent maximum, and droops of 1.0 percent maximum, where the tolerances are expressed as a percentage of the staircase (cumulative stairstep) voltage amplitudes at the tube signal input electrode. 3. Procedure. Either method A or B may be used to determine the gray scale response. 3.1 Method A. This method measures the gray scale response under dynamic conditions of continuous writing, reading, and erasing. a. Operating conditions shall be as specified in the TSS. b.
Read the area specified in the TSS and display the output on both the oscilloscope and monitor. The orientation of the reading raster shall be such that each line of the reading raster, within the specified area, scans all the steps of the stored gray scale pattern. c. Operate the TUT with a storage time such that a signal written to 90 percent of saturation will decay to 10 percent of saturation in the time specified. d. Write the gray scale video test pattern and adjust the write scan size so that the pattern covers the area specified in the TSS. e. Write and read the TUT with the storage time as utilized in 3.1c.
Adjust the video test signal amplitude and write gun bias so that an equilibrium condition is obtained with the lowest amplitude step just written and the maximum number of steps discernible on the oscilloscope. Confirm that the TUT has reached an equilibrium condition after these writing adjustments have been made by waiting at least 10 times the decay period utilized in 3.1c. f. After confirming that the TUT has reached equilibrium, count the number of steps of the gray scale test pattern visible in the output of the oscilloscope. This is the gray scale response (dynamic).
To be counted, each step must be distinguishable on the oscilloscope display from the adjacent step along the entire step transition within the specified area. Use the line selector on the oscilloscope to check the entire specified area. METHOD 5420 12 December 1972 5420-1