Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 TABLE 5422-II. Example of a computer run. A computer run using the data from table I in 3h of the method. Following the run is a list of the steps in the computer program. INTRODUCTION THIS PROGRAM WILL CALCULATE THE MTF AND THE TANGENT OF PHI (THE PHASE SHIFT) FROM LINE SPREAD (IMPULSE RESPONSE) DATA WHEN THE FOLLOWING QUESTIONS HAVE BEEN ANSWERED. INTERROGATION STATEMENTS FOLLOWED BY TYPICAL ANSWERS WHAT IS THE MOST NEGATIVE VALUE OF X? -15 WHAT IS THE MOST POSITIVE VALUE OF X? 20 WHAT IS THE TIME INTERVAL BETWEEN DATA POINTS IN MICROSECONDS? .02 HOW MANY VALUES OF Y ARE THERE? 36 NOW ENTER THE 36 VALUES OF Y?
0, 1, 2.8, 5, 7.5, 11, 15, 21, 29, 40, 51, 62, 70, 75, 80, 82, 82, 80, 72.5, 64, 55, 47, 38.5 ? 30, 23, 18, 14, 11, 9, 7, 5.2, 3.8, 2.4, 1.3, .8, 0 WHAT IS THE ACTIVE SCAN LINE TIME IN MICROSECONDS? 25 WHAT FRACTION OF THE SSRD IS THE SCAN LENGTH? .143 WHAT IS THE MAXIMUM NUMBER OF CYCLES (DIVISIBLE BY 25) FOR WHICH MTF IS REQUIRED? 600 METHOD 5422 12 December 1972 5422-7