Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5430 GAS RATIO (Vidicons) 1. Gas ratio shall be determined as follows: With no light incident on the tube face, focus coil current "Off", scanning "On" or beam deflected, Esj open, Ef = 6.3 V or as specified, the following tests shall be made: Ec1 Ec3 Test procedure Unit 0 V 0 V 250-400 V dc -100 V dc Record G3 current as PIc3 Record G3 current as NIc3 when leakage becomes relatively stable, but not necessarily zero. Record G3 current as ILc3 mA dc nA dc -150 V -100 V dc nA dc Gas ratio (Gr) = 3 )3 3 ( PIc ILc NIc 2. The gas ratio (Gr) shall be within the limit(s) specified. METHOD 5430 5430-1 28 March 1975