Beckhoff Automation GmbH & Co. KG TF2000 — 4.3.1 Quick start

Configuration | ADS р The server has been initialized in the path /usr/local/etc/TwinCAT/Functions/TF2000-HMI-Server/service . To display further settings, use the command TcHmiSrv --help Firewall 1. Open pf.conf to configure the firewall. doas ee /etc/pf.conf 2. Add the port 2020. pass in quick proto tcp to port 2020 keep state 3. Save and exit the editor. 4. Enter the command to reload the rules. The firewall must be activated for this. р Port 2020 has been released for the HMI server. doas pfctl -f /etc/pf.conf 4.2.3.1 Commands | Commands Overview of all commands: TcHmiSrv --help Initialize server:

The server is initialized in the path /usr/local/etc/TwinCAT/Functions/TF2000-HMI-Server/service doas TcHmiSrv --initialize --password= Server start/stop/restart: doas service TcHmiSrv start doas service TcHmiSrv stop doas service TcHmiSrv restart Factory reset: Reset all services. doas TcHmiSrv --factoryReset --storageDir=/usr/local/etc/TwinCAT/Functions/TF2000-HMI-Server/service Reset a specific service. doas TcHmiSrv --factoryReset --storageDir=/usr/local/etc/TwinCAT/Functions/TF2000-HMI-Server/ service/ Follow the steps below to reinitialize the server.

doas service TcHmiSrv stop doas TcHmiSrv --initialize --password= doas service TcHmiSrv start 4.3 ADS | ADS The Automation Device Specification is the TwinCAT communication protocol. This can be used to access the individual modules. 4.3.1 Quick start | Quick start To start, create or open a TwinCAT HMI project. Installation Installation is not necessary. This package is an integral part of the HMI Server. Configuration of the ADS extension 1. Open the server configuration page. TF2000 33 Version: 1.8.0