Configuration | ADS In a future version of the TwinCAT HMI, it will be possible to call the methods directly via the Actions and Conditions Editor without using JavaScript/TypeScript. Methods must always be called explicitly and cannot be used as a control attribute. Note that calling a method from the HMI results in the execution of PLC code. Available from version 1.12. 4.3.2.4 Pointers and references | Pointers and references User-defined structures with references and pointers as member variables can be read and written using dereferencing if the PLC data type has been marked with the PLC attribute TcGenerateDeRefType.
Available starting with HMI Server version 14.3.76 and TwinCAT version 4026.20 With version 1.12.748.0, references , pointers , and interface pointers can be resolved in the HMI. This makes it possible to access the original variable being pointed to via the pointer or reference. It can be read and written when accessed via the pointer or reference. The resolved pointers or references are listed as usual under the variables in the TwinCAT HMI Configuration Window. Changing the addresses of the pointers or references so that they point to another variable is not possible in the HMI. This must be done in the PLC. Available since version 1.12.748.0.
4.3.3 ADS Server Interface | ADS Server Interface The HMI Server's ADS Server When the HMI server is started as a service, the service manager opens an ADS server on port 19800. This ADS server can be used to discover and get the state of HMI server instances that are managed by the service manager. TF2000 42 Version: 1.8.0