Configuration | TcHmiUserManagement WARNING Allowing general access You can allow all requests using “.*”. This is a significant security vulnerability and should be used exclusively for testing and development purposes. This setting is expressly not recommended for production systems. To access a server over the network, at least one of the following requirements must be met: The IP address or host name used is listed in the certificate. The IP address or host name used is configured under “Allowed Origins”. If these requirements are not met, access can alternatively be gained via an SSH tunnel. This is helpful, for example, on a Linux® system without a connected monitor. 1.
To do this, open PowerShell. 2. Run the following command, replacing with the IP address or hostname of the external device. 3. Open a local browser. ssh -N -L 2020:localhost:2020 Administrator@ 4. You can now access your external server using the following URL https://127.0.0.1:2020/Config 5. Navigate to TcHmiSrv/Security 6. Adjust the “Allowed Origins” entry accordingly to allow future connections even without an SSH tunnel. р After saving, you can access the server directly using the newly configured IP address or host name.
4.5 TcHmiUserManagement | TcHmiUserManagement 4.5.1 Two-factor authentication | Two-factor authentication To use an authenticator app (e.g., Microsoft or Google) as a second factor, open the HMI server’s configuration page via the HMI Systray and proceed as follows: 1. Open the TcHmiUserManagement Extension tab (1), navigate to the Users section (2), and enable two- factor authentication (3) TF2000 51 Version: 1.8.0