beckhoff TF3300 — 4.2.1 Automated export

Configuration When exporting, the oversampling signals are now saved in addition to the other signals and time stamps. Here, all signals which have the same oversampling rate and thus a new identical sampling rate are grouped and stored with the same time series. Export IoT File Arrays as Oversampling Symbols to CSV To export an array symbol from an IoT file as an oversampling signal to a CSV file, only the array signal is selected in the signal selection. Separate tables are created for the different sampling rates of the selected signals. All signals with the same array length are thus grouped in a table. This means that all signals in a table have a value at any time.

If several signals with different sampling rates are selected during the export, the table name, which can be set in the configuration ("Config"), serves as the base name for the new tables. The sampling rate is appended after the base name (e.g. ExportTable_200_ms). TF3300 24 Version: 1.3.1