beckhoff TF4100 — 4.2.1.4.15 FB_CTRL_SERVO_MOTOR_SIMULATION

PLC API 4.2.1.4.15 FB_CTRL_SERVO_MOTOR_SIMULATION The behavior of an actuator can be simulated with this function block. Behavior of the output Inputs VAR_INPUT bMovePos : BOOL; bMoveNeg : BOOL; fManSyncValue : FLOAT; bSync : BOOL; eMode : E_CTRL_MODE; END_VAR TF4100 112 Version: 2.2.4 Name Type Description bMovePos BOOL Input that moves the simulated actuator in the positive direction. bMoveNeg BOOL Input that moves the simulated actuator in the negative direction. fManSyncValue FLOAT Input with which the simulated motor position can be set, or the value to which movement takes place in manual mode.

bSync BOOL A rising edge at this input sets the simulated motor position to the value "fManSyncValue". eMode E CTRL MODE _ _ Input that specifies the operation mode [} 173] of the function block.