PLC API Description of the output behavior 2 Inputs VAR_INPUT fPwmInput : FLOAT; eMode : E_CTRL_MODE; END_VAR Outputs VAR_OUTPUT bPwmOutBitPos : BOOL; bPwmOutBitNeg : BOOL; eState : E_CTRL_STATE; bError : BOOL; eErrorId : E_CTRL_ERRORCODES; END_VAR TF4100 143 Version: 2.2.4 Name Type Description fPwmInput FLOAT Input value for the function block eMode E CTRL MODE _ _ Input that specifies the operation mode of the function block.