Тексел ТХ01-RS — 6.1 Principle of operation

• sensors with a dry contact type output (reed switches). The counting input of the device receives pulses from a sensor that controls one or more marks on the motor shaft. The levels of the input signals are converted and processed in the matching unit , after which they are sent to the digital processing unit , where it occurs: • filtering of input signals; • measuring the instantaneous value of the shaft speed; • measurement of operating time at the operating time counter; • conversion of measured values into real physical quantities; • scaling of values before their output to the display; • generation of signals for controlling the outputs according to a specified algorithm.

NOTICE The parameter-current/voltage conversion is carried out using the built-in output of a ten-digit DAC. The signals obtained after the conversion can be used to register parameters. Control unit includes buttons for entering parameters and controlling the operation of the device. Display unit displays the measurement results or operating parameters on the indicators and shows the device status using LEDs. Internal power supply , depending on the version of the device (with AC or DC power), converts the supply voltage for all units of the device and generates a signal indicating the loss of supply voltage.

It also generates a DC voltage to power the sensors connected to the inputs of the device. Using the RS-485 interface, the device is connected to a PC, which makes it possible to set and edit the configuration of the device, to monitor its current status and readings. 28