7.3 Output settings Device digital output (type P) functions as a comparison device (comparator). The input value of the comparison device: • tachometer measurement result ( SrcC = tACHo ) – control mode is selected using the oUtdo parameter; • measured value of the operating time ( SrcC = LiFE_T ) – the output is switched on when the setpoint is reached to control the digital output for the operating time UdAY , UHour , UMin , USEc . When the output is turned on, the ВЫХ LED lights up. It is possible to work according to one of the following types of logic (see Figures 7.6 and 7.7 ):
• reverse hysteresis ( oUtdo = 1) – output turns on at values F current > (U+Δ) and turns off at values F current • direct hysteresis ( oUtdo = 2) – output turns on at values F current F current > (U+Δ); • П-shaped logic ( oUtdo = 3) – output is turned on at values (U-Δ) current • U-shaped logic ( oUtdo = 4) – output is turned on with the values F current current > (U + Δ). 42