EPSON — 2D Symbol Font Settings

Chapter 4 Handling The following table shows the recommended value for the 2D symbol module. Recommended value for setting the barcode/2D symbol font (2D symbol of stack type) 4 - : Not supported. * 1 : Whether paper feed is performed during printing 2D symbol can be checked in [ Display Media Feed Position ] - [ Display Print Preview ] in the Print Preview function. For this function, see "Print Preview" on page 182 . *2: Specify when using PDF417.

175 Symbol Category Print Quality Print Status (*1) Adjust Bar Width (*2) Minimum Module [by 360 dpi] ANSI Grade D or higher ANSI Grade C or higher ANSI Grade B or higher PDF417 GS1 DataBar Stacked GS1 DataBar Stacked Omnidi- rectional GS1 DataBar Expande d Stacked Plain Media, Plain Media Label Speed No Paper feed 3 6 dot - - With Paper feed 6 dot - - Quality No Paper feed 6 dot - - With Paper feed 6 dot - - Fine Media, Fine Media Label, Synthetic Media Label, PET Film Speed No Paper feed 4 dot - - With Paper feed 4 dot - (*2) - Quality No Paper feed 4 dot - - With Paper feed 4 dot - (*2) -