EPSON — 2D Symbol Printing

Chapter 4 Handling Specifying the 2D symbol data See the following description to specify the 2D symbol data. For the composite symbol and the HRI character, see "Specifying the barcode data" on page 72 . PDF417 ❏ Calculated automatically when the digit number and the line number are 0. ❏ To specify other number than 0, make sure the multiplication of the digit number and the line number is under 928. QRCode ❏ Size is determined by the specified version. If it does not fit in the specified version, it is changed automatically to the appropriate version. GS1 DataBar Stacked /GS1 DataBar Stacked Omnidirectional ❏ Up to 13 digits of data can be specified.

❏ Do not specify the application identifier ‘01’ for the head of the data. ❏ A check digit need not to be attached to the data. GS1 DataBar Expanded Stacked ❏ Multiple line symbol version of GS1 DataBar Expanded. How to specify the data is the same as GS1 DataBar Expanded. (For details, see "GS1 DataBar Expanded" on page 76 .) 4 81