Tutorials Fig. 23: Figure 1: Calling "Create default mappings" This functionality iterates over all Symbols within the original PLC projects and tries to bind it to simulation symbols of the same symbolic name / access path, same data type but reversed location (reversed %I / %Q). If an applicable simulation symbol exist, an local (IO-Mapping) or remote Mapping (via Realtime Network Variables) will be created within the simulation settings. Standard mappings are very useful when used in conjunction with the Create Simulation project [ } 31] feature.
This feature ensures that the symbolic names and access paths within the simulation project are easily connectable to the original PLC project for the user and automatic program support by ensuring identical naming conventions. In Figure 2 the navigator window has the original Symbol 'bRun' selected. The 'Simulation Targets View' on the right hand side shows the possible connections within the assigned simulation PLC project. The Default Mapping for this symbol is 'MAIN.bRun' and is marked with green text. Fig. 24: Figure 2: Simulation Mapping Targets View: Before creating the Default Mappings TS1110 36 Version: 1.0