beckhoff TS1110 — 5.1.2 Navigation Window

User interface All shown items that are bound to simulation settings (e.g. Variables / Symbols, Axes, Devices, PLC projects, ...) are marked with a red 'S' in their icon. The different functionalities of the TwinCAT Simulation Manager are triggered mainly via the 'Navigation Window' context menu. Depending in the selected item in this view, the context menu can contain the commands shown in Table 1. Requirements Table 1: Context Menu commands A few examples for the Context Menu on the most important items for the Simulation project are given in the following. TS1110 40 Version:

1.0 Menu entry Click context Description Create Simulation PLC-Project Original PLC selected, Simulation PLC not assigned A Template Simulation PLC project is created and bound to the selected Original PLC (see Create Simulation Project [} 31]). Add Simulation Variables ... Original PLC selected, Simulation PLC assigned Maintains new Symbols of the Original PLC into the Simulation PLC (see Add Simulation Symbols [} 34]). Download PLC Symbols PLC selected Downloads the *.tpy Symbol information from the target and store them in the local cache of the simulation project. Internal data will be updated.

Import PLC Project PLC selected Imports an "external" PLC Control project for local (cached) access. Be sure that the PlcControl project is the actual project running on the target! Open PlcControl PLC selected Opens the PLCControl application for the specified PLC. Precondition is, that the *.pro file was created by the simulation manager (via the Create Simulation Project [} 31] command), or was imported by the Import PLC Project Rescan PLC selected Rescans the symbols of the PLC project Ping Target System selected Pings the target system with a UDP-message. If the target is connected to the same subnet and is running, the Ping will succeed.

AdsPing Target System selected Pings the target system via ADS. In addition that the target is reachable via UDP, both systems must run a TwinCAT environment (in 'Run' or 'Config' mode) and both systems must refer each other via ADS Routes. Open System Manager Target System Selected Opens the System Manager on the locally cached configuration (*.tsm) downloaded from the target. This configuration should be always the actual configuration of the target. Download current configuration Target System Selected Downloads and caches the 'Current Configuration' from the target. PlcExplorer Taget System Selected Shows a dialog-browser showing the current PLC runtimes of the target.

WebConfiguration Target System Selected Opens the WebConfiguration HTML page of the target. If this service is not supported and/or the Web-Server is not running on the target, an error message will be displayed. Disable Device(s) Selected Disables the Device(s) for the simulation profile Enable Device(s) Selected Enables the Devices(s) for the simulation profile Simulation Axis Selected Decouples the Axis in Simulation Mode and sets an 'Simulation Encoder'. Properties All Opens the Properties dialog.