beckhoff TS1110 — 7 First steps

First steps Fig. 64: Picture 13: Simlation Symbols without mapping to the original PLC The manual configuration works simply be clicking the checkboxes (or context menu) on the appropriate symbols (see Picture 13 [ } 73] ) within the mapping targets view (upper right-hand-side list box). Dependent of the selection of the symbol in the left-hand-side "Configuration" navigation tree the mapping targets view collects all "Original" or "Simulation" symbols with the same datatype within its list. Potentially every single symbol of these target symbols can be bound to the source symbol.

The automatic configuration happens if "Create Default Mappings" is activated from the "Edit" main menu of the TwinCAT Simulation Manager ( Picture 14 [ } 73] ). This functionality iterates over all Symbols within the original PLC projects and binds it to simulation symbols of the same symbolic name / access path, same datatype but reversed location (see Picture 15 [ } 73] ). This should be the default option because it ends up with a good standard configuration that can be fine tuned manually afterwards. TS1110 76 Version: 1.0