beckhoff TS1110 — 2 TwinCAT Simulation Manager

TwinCAT Simulation Manager Administration and configuration of simulation environments / profiles Simulation of I/O devices and axes Simple and secure switchover into simulation mode "Virtual device" and "virtual function" libraries Automatic creation of a real-time capable simulation PLC project framework with symbols and commentaries taken over from the original project Use of all the options of the PLC programming environment, also in simulation code: e.g. graphic programming, tracing, debugging etc. Principle of operation I/O devices and axes are initially connected to the PLC. If parts of the machine are to be simulated, then the devices in question must be deactivated.

The performance of the relevant inputs and outputs must be replicated as exact as possible so that the machine PLC – henceforth referred to as the original PLC – can continue to perform its functions. This is carried out by the simulation PLC, which connects itself to the system in place of the inactive I/O devices. For coupling, the mapping from the original PLC to the inactive device must be broken and rerouted to the simulation PLC. Deactivated axes are replicated by a simulation axis; any latch functionalities in the simulation PLC are implemented. Simulated axes are switched over to 'free running' in the ' TwinCAT Simulation Manager '. TS1110 9 Version: 1.0