beckhoff TS511x — 6.2.1 General NC Errors

Error Codes TS511x 42 Version: 1.0 Error(Hex) Error(Dec) Error Type Description The parameter for activating or deactivating the function “cyclic monitoring of NC setpoint issuing on continuity and consistency” is invalid. (Special function.) 4004 16388 Internal External Error This error code can be set by an external module (e.g. third-party module) or can be set when an external module exhibits an error. 4010 16400 Parameter "Channel identifier not allowed" Either an unacceptable value (not 1...255) has been used, or a channel that does not exist in the system has been named.

4011 16401 Parameter "Group identifier not allowed" Either an unacceptable value (not 1...255) has been used, or a group that does not exist in the system has been named. 4012 16402 Parameter "Axis identifier not allowed" Either an unacceptable value (not 1...255) has been used, or an axis that does not exist in the system has been named. 4013 16403 Parameter "Encoder identifier not allowed" Either an unacceptable value (not 1...255) has been used, or a encoder that does not exist in the system has been named. 4014 16404 Parameter "Controller identifier not allowed" Either an unacceptable value (not 1...255) has been used, or a controller that does not exist in the system has been named.

4015 16405 Parameter "Drive identifier not allowed" Either an unacceptable value (not 1...255) has been used, or a drive that does not exist in the system has been named. 4016 16406 Parameter "Table identifier not allowed" Either an unacceptable value (not 1...255) has been used, or a table that does not exist in the system has been named. 4020 16416 Internal "No process image" No PLC-axis interface during creation of an axis. 4021 16417 Internal "No process image" No axis-PLC interface during creation of an axis. 4022 16418 Internal "No process image" No encoder-I/O interface during creation of an axis.

4023 16419 Internal "No process image" No I/O-encoder interface during creation of an axis. 4024 16420 Internal "No process image" No drive-I/O interface during creation of an axis. 4025 16421 Internal "No process image" No I/O-drive interface during creation of an axis. 4030 16432 Internal "Coupling type not allowed" Unacceptable master/ slave coupling type. 4031 16433 Internal "Axis type not allowed" Unacceptable type specification during creation of an axis. 4032 16434 Parameter Unknown Channel Type The NC channel type is unknown. Known types are e.g. an NCI channel, a FIFO channel, etc.. 4040 16448 Internal "Axis is incompatible" Axis is not suitable for the intended purpose.

A high speed/low speed axis, for example, cannot function as a slave in an axis coupling.