Error Codes TS511x 69 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 4337 17207 Parameter Parameter “Couple Slave to Actual Values if not Enabled” is Invalid The parameter “Couple Slave to Actual Values if not Enabled” is invalid. Range of values: [0, 1] Unit: 1 4338 17208 Parameter Parameter "Allow Motion Commands to Slave Axis” is Invalid The boolean parameter “Allow Motion Commands to Slave Axis” is invalid. This parameter defines whether a motion command can be sent to a slave axis or whether this is rejected with the NC error 0x4266 or 0x4267. Range of values: [0, 1] Unit:
1 4339 17209 Parameter Parameter “Allow Motion Commands to External Setpoint Axis” is Invalid The boolean parameter “Allow Motion Commands to External Setpoint Axis” is invalid. This parameter defines whether a motion command may be send to an axis within the state of external setpoint generation or whether such a message is rejected with error 0x4257. Range of values: [0, 1] Unit: 1 433A 17210 Parameter Parameter “Fading Acceleration” is Invalid The parameter “Fading Acceleration” for the blending profile from set to actual values is invalid.
This parameter defines how to blend from a setpoint based axis coupling to an actual value based coupling (indirectly there is a time for the blending). Note: The value 0.0 causes that the minimum of default acceleration and default deceleration is used as blending acceleration internally within the NC. Range of values: [0; 0.01 .. 1.0e+20] Unit: e.g. mm/s^2 Error(Hex) Error(Dec) Error Type Description 433B 17211 Parameter "Fast Axis Stop Signal Type not allowed" The value for the Signal Type of the 'Fast Axis Stop' is not allowed [0...5]. 4340 17216 Initialization "Axis initialization" Axis has not been initialized.
Although the axis has been created, the rest of the initialization has not been performed (1. Initialization of axis I/O, 2. Initialization of axis, 3. Reset axis). 4341 17217 Address "Group address" Axis does not have a group, or the group address has not been initialized (group contains the set value generation). 4342 17218 Address "Encoder address" The axis does not have an encoder, or the encoder address has not been initialized. 4343 17219 Address "Controller address" The axis does not have a controller, or the controller address has not been initialized. 4344 17220 Address "Drive address" The axis does not have a drive, or the drive address has not been initialized.
4345 17221 Address "Axis interface PLC to NC address" Axis does not have an axis interface from the PLC to the NC, or the axis interface address has not been initialized.