beckhoff TS511x — 6.2.4 Axis Errors

Error Codes TS511x 71 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 435E 17246 Monitoring "Looping distance less than breaking distance" The absolute value of the looping distance is less or equal than the positive or negative breaking distance. This is not allowed. 435F 17247 Monitoring Starting Velocity Invalid The required starting velocity for a positioning task is not permitted (usually the starting velocity is zero). This situation can occur if the velocity is smaller than or equal to zero, greater than the axis maximum permitted velocity or for servo motion controllers greater than the axis reference velocity (see axis and motion controller parameters).

4360 17248 Monitoring Final Velocity Invalid The required final velocity for a positioning task is not permitted (normally the final velocity is zero). This situation can occur if the velocity is smaller than or equal to zero, greater than the axis maximum permitted velocity or for servo motion controllers greater than the axis reference velocity (see axis and motion controller parameters). 4361 17249 Monitoring "Time range exceeded (future)" The calculated position lies too far in the future (e.g. when converting a position value in a DC time stamp). 4362 17250 Monitoring "Time range exceeded (past)" The calculated position lies too far in the past (e.g.

when converting a position value in a DC time stamp). 4363 17251 Monitoring "Position cannot be determined" The requested position cannot be determined. Case 1: It was not passed through in the past. Case 2: It cannot be reached in future. A reason can be a zero velocity value or an acceleration that causes a turn back. 4364 17252 Monitoring "Position indeterminable (conflicting direction of travel)" The direction of travel expected by the caller of the function deviates from the actual direction of travel (conflict between PLC and NC view, for example when converting a position to a DC time).

4370 17264 Monitoring No Slave Coupling Possible (Velocity Violation) A slave coupling to a master axis (e.g. by a universal flying saw) is rejected because otherwise the maximum velocity of the slave axis would be exceeded (a velocity monitoring has been selected). 4371 17265 Monitoring No Slave Coupling Possible (Acceleration Violation) A slave coupling to a master axis (e.g. by a universal flying saw) is rejected, because otherwise the maximum acceleration of the slave axis will be exceeded (an acceleration monitoring is selected).

4372 – 438B 17266 – 17291 See TF5055 NC Flying Saw – Error Codes 43A0 17312 Internal "Axis consequential error" Consequential error resulting from another causative error related to another axis. Axis consequential errors can occur in relation to master/slave couplings or with multiple axis interpolating DXD groups.