Error Codes TS511x 85 Version: 1.0 Error(hex) Error(dec) Error Type Description 4625 17957 Parameter Parameter for the “Motion Controller Operation Mode” is Invalid The parameter for the motion controller operation mode (position mode, velocity mode, torque mode, …) is invalid. Possibly, an NC operation mode switching has been tried or at TC system start has been tried to activate a preconfigured operation mode. Annotations: The generic operation modes defined within the NC are realized by the NC motion controller specifically, i.e. in particular for the protocols SERCOS/ SoE and CANopen/ CoE (DS402).

In this connection, protocol specific, motion controller specific or even customer specific peculiarities have to be obeyed (e.g. regarding SERCOS/ SoE merely in the SERCOS parameter range S-0-0032 to S-0-0035 predefined operation modes can be activated at runtime). Furthermore, not every generic NC operation mode can be converted into a motion controller specific operation mode (here gaps within the specification may exist). The generic NC operation mode 0 forms a special case. This value is used as a mark to activate an NC default operation mode (as long as this mark is known to the NC). Range of values: [0, >=1] Unit:

1 4626 17958 Monitoring Motion Controller Functionality is Not Supported A motion controller functionality has been set off that has not been released for usage or has not been implemented (e.g. writing or reading of a motion controller mode that is not supported by certain motion controllers). It is also possible that this functionality is merely not supported at times (e.g. because the motion controller device resides in error state or a motion controller enable is missing). 4627 17959 Function DRIVEOPERATIONMODEBUSY. The activation of the motion controller controlling mode has failed because another object with OID… uses this interface already.

4628 17960 Monitoring Motion Controller Operation Mode Switching has not been configured or the desired motion controller operation mode cannot be found There has not any motion controller operation mode switching been configured and thus no reading or writing of a motion controller operation mode is possible. Or the desired motion control operation mode has not been found in the list of the predefined motion controller operation modes (e.g. for SoE/ SERCOS). Annotation for CoE motion controllers:

The reading or writing of the CoE Motion Control Operation Mode is merely possible if the CoE objects 0x6060 Modes Of Operation and 0x6061 Modes Of Operation Display can be found in the cyclic process data (PDO list) and a valid default operation mode has been configured. Annotation for SoE motion controllers: The reading or writing of the current SoE Motion Controller Operation Mode is merely possible if this operation mode has been predefined in one of the SoE Parameters S-0-0032 to S-0-0035. 0x4630 … 0x463F: Error codes are reserved for external motion controller errors (e.g. stepper motor terminal or function block MC PowerStepper). _