beckhoff TS6271 — 5.3.1 Project planning of the PROFINET device

Devices at protocol OutputCR is the output direction, these are the frames that the controller sends to the Devices. 0x0100 = At least one InputCR is invalid The data of InputCR are invalid. 0x0200 = At least one InputCR Provider is in stop The Input CR is in stop mode. The device application is held in STOP, the cause should be clarified on the device side. 0x0400 = At least one InputCR Problemindicator is set A problem was detected in the device. The diagnostic buffer in the Device contains at least one message. These can be read out via the corresponding records. 0x1000 = At least one OutputCR is invalid The data of OutputCR are invalid.

0x2000 = At least one OutputCR Provider is in stop The Output CR is in stop mode. This indicates that the triggering IO Task or PLC is stopped. 0x4000 = At least one OutputCR Problemindicator is set A problem was detected in the controller. The diagnostic buffer in the controller contains at least one message. These are displayed e.g. via the DiagHistory. On the one hand information about the status of the IO Controller Single AR is displayed here. In addition, collective statuses are formed from the Frame Data statuses of the individual CRs. The whole thing happens for the input and the output CRs (currently only one is possible; in future the controller will support several CRs).

In addition a PROFINET alarm is also displayed in the “PnIoBoxDiag” 5.3 Settings 5.3.1 Project planning of the PROFINET device When establishing a PROFINET connection the controller always assigns an IP address to the device from its own address space (if the device does not yet have one or if it has a different one). In TwinCAT the next higher address is taken for a device by default (starting from the controller adaptor class); the subnet and gateway are the same as those of the controller. Before the actual assignment of the IP address to the device by the controller, an ARP is used to test for a possible address conflict or to check whether the device already has this IP address.

If there is a conflict, e.g. that the IP address is already assigned in the network, the IO driver determines this and outputs a corresponding message in the logger window. If there is no reply to the ARP, this means that no device (the projected device included) is using this IP configuration, which in turn results in the controller assigning the IP settings to the device via a DCP_SET. Setting is skipped if it is determined via the ARP that the device sought already has the projected IP address. TS6271 46 Version: 1.2