TwinCAT library and programming 6.1.10 FB_PN_GET_PORT_STATISTIC When called, this module supplies the statistical data for the ports of a PROFINET device. VAR_INPUT VAR_INPUT bStart : BOOL; NETID : T_AmsNetId;(* AMS Net ID from Controller *) PORT : T_AmsPort; (* Port used by Controller to communicate with Device *) END_VAR bStart : The block is activated by a rising edge on this input NETID : AMS Net ID of the controller PORT : Port via which the controller communicates with the device (port = Device ID + 1000hex ) VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; str_RemotePort_1 : str_GetPortStatistic; str_RemotePort_2 : str_GetPortStatistic; bPort1 : BOOL; bPort2 : BOOL; END_VAR bBusy :
When the function block is activated this output is set. It remains set until a feedback is received. While Busy = TRUE, no new command will be accepted at the inputs. str_RemotePort_1 : This structure [ } 67] contains the statistical data for Port 1. str_RemotePort_2 : This structure contains the statistical data for Port 2. bPort1 : Is TRUE if the port has a link. bPort2 : Is TRUE if the port has a link. Requirements TS6271 63 Version: 1.2 Development environment Target platform PLC libraries to be linked TwinCAT v2.11.0 R3 PC or CX (x86, ARM) TcProfinetDiag.Lib