TwinCAT library and programming OperatingStatus : STRING(16); RxOctets : DWORD; RxUniCastPackets : DWORD; RxBadPackets : DWORD; RxDroppedFrames : DWORD; RxUnknownProtocol : DWORD; TxOctets : DWORD; TxUniCastPackets : DWORD; TxBadPackets : DWORD; TxDroppedPackets : DWORD; END_STRUCT END_TYPE 6.2.7 str_PortDiag All port diagnostic information is represented in the data structure str_PortDiag . TYPE str_PortDiag : STRUCT PortId : STRING(128); PortDescription : STRING(128); SystemName : STRING(128); SystemDescription : STRING(128); ChassisId :
STRING(128); END_STRUCT END_TYPE 6.2.8 ST_PN_DiagMessage The data structure ST_PN_DiagMessage contains the complete data stream of a diagnostic message that is sent by a PROFINET on request. This data stream is evaluated in the FB_PN_ALARM_DIAG function block and is copied to a readable structure. TYPE ST_PN_DiagMessage : STRUCT nFlags : WORD; nTextID : WORD; TimeStamp : ARRAY[0..7] OF BYTE; nData : ARRAY[0..299] OF BYTE; END_STRUCT END_TYPE 6.2.9 ST_PN_Diag The data structure ST_PN_Diag contains a diagnostic message from a terminal that is connected via a PN device and a controller. TYPE str_PortDiag : STRUCT strTimeStamp : ARRAY[0..7] OF BYTE; nAPI : DWORD; nSlot : WORD; nSubSlot :
WORD; nAlarmType : WORD; nAlarmSpecifier : WORD; nUserStructIdentifier : WORD; nChannelNumber : WORD; nChannelErrorTyp : WORD; nChannelProperties : WORD; nExtChannelErrorTyp : WORD; arSpare : ARRAY [1..9] OF WORD; arUserSpecificData : ARRAY [0..19] OF BYTE; END_STRUCT END_TYPE The information content of the structure corresponds to that of the Diag History, which is displayed in the system manager. TS6271 68 Version: 1.2