beckhoff TS6420 — 6.5.10 ODBC - DB2 Database

Configuration To get the functionality of an AutoID a sequence will be create at the scheme you use with the following attributes: name: "mytable_ID_seq" raise step: "1" minimum: "1" An AutoID is generated in the "ID" column. The value in this column is, in other words, always increased by 1. This functionality makes the sequence possible. The "Timestamp" column stores the time at which the data record was saved. The name of the variable is stored in the "Name" column. The "Value" column stores the value of the variable. 6.5.10 ODBC - DB2 Database The values of the variables are saved in a DB2 Database. The variable values are saved in the following table structure. TS6420 45 Version:

1.2 Column name Data type Null permitted Characteristic name text no ValueType="Double" value double precision no ValueType="Bytes" value BLOB no E DBColumnTypes _ PostgreSQL PLC Control eDBColumn BigInt _ bigint DINT eDBColumn Integer _ integer DINT eDBColumn SmallInt _ smallint INT eDBColumn TinyInt _ smallint INT eDBColumn Bit _ bit BYTE eDBColumn Money _ money LREAL eDBColumn Float _ double precision LREAL eDBColumn Real _ real REAL eDBColumn DateTime _ timestamp DT eDBColumn NText _ text STRING eDBColumn NChar _ character STRING eDBColumn Image _ bytea ARRAY OF BYTE eDBColumn NVarChar _ character varying STRING eDBColumn Binary _ bytea ARRAY OF BYTE eDBColumn VarBinary _ bytea ARRAY OF BYTE Column name Data type Null permitted Characteristic ID BIGINT no IDENTITY (1,1) Timestamp TIMESTAMP no Name VARCHAR no ValueType="Double" Value DOUBLE no ValueType="Bytes" Value BLOB no