PLC API 7.1.6 FB_GetDBXMLConfig With this function block FB_GetDBXMLConfig all declared databases can be read out of the XML- configuration file. VAR_INPUT VAR_INPUT sNetID : T_AmsNetId; cbDBCfg : UDINT; pDBCfg : POINTER TO ARRAY [0.. MAX_XML_DECLARATIONS] OF ST_DBXMLCfg bExecute : BOOL; tTimeout : TIME; END_VAR sNetID : Is a string containing the AMS network identifier of the target device to which the ADS command is directed. cbDBCfg : Returns the length of the array in which the configurations will be write. pDBCfg : Provides the pointer address of the array in which the configurations will be write. bExecute : The command is executed with the rising edge. tTimeout :
States the time before the function is cancelled. VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; bError : BOOL; nErrID : UDINT; END_VAR bBusy : The command is in the process of being transmitted by ADS. No new command will be accepted as long as "bBusy" remains TRUE. bError : Becomes TRUE, as soon as an error occurs. nErrID : Supplies the ADS Error Code [ } 132] when the bError output is set. Requirements TS6420 65 Version: 1.2 Development environment Target system type PLC libraries to be linked TwinCAT v2.10.0 CX (ARM) Development environment Target system type PLC libraries to be linked TwinCAT v2.10.0 PC oder CX (x86) TcDatabase.Lib TwinCAT v2.10.0 CX (ARM)