PLC API You can open connections to databases with this function block FB_DBConnectionOpen. This can improve the read and write access speed with the fuction blocks FB_DBWrite, FB_DBRead, FB_DBRecordInsert and FB_FBRecordSelect. VAR_INPUT VAR_INPUT sNetID : T_AmsNetId; hDBID : DINT; bExecute : BOOL; tTimeout : TIME; END_VAR sNetID : Is a string containing the AMS network identifier of the target device to which the ADS command is directed. hDBID : Indicates the ID of the database to be used. bExecute : The command is executed with the rising edge. tTimeout : States the time before the function is cancelled. VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; bError : BOOL; nErrID : UDINT; sSQLState :
ST_DBSQLError; END_VAR bBusy : The command is in the process of being transmitted by ADS. No new command will be accepted as long as "bBusy" remains TRUE. bError : Becomes TRUE, as soon as an error occurs. nErrID : Supplies the ADS Error Code [ } 132] or the TcDatabaseSrv_Error_Codes [ } 135] when the bError output is set. sSQLState : Supplies the SQL error code [ } 89] of the specified database type. Requirements 7.1.9 FB_DBConnectionClose You can close connections to databases with this function block FB_DBConnectionOpen. If you have opened a connection to a database before, it is important to close this connection after using. VAR_INPUT VAR_INPUT sNetID : T_AmsNetId; hDBID :
DINT; bExecute : BOOL; tTimeout : TIME; END_VAR TS6420 67 Version: 1.2 Development environment Target system type PLC libraries to be linked TwinCAT v2.10.0 PC oder CX (x86) TcDatabase.Lib TwinCAT v2.10.0 CX (ARM)