PLC API sSQLState : Supplies the SQL error code [ } 89] of the specified database type. Requirements 7.1.15 FB_DBRecordDelete The FB_DBRecordDelete function block allows to delete data records out of a database. The length of the SQL - command could be till 10000 symbols. For using this function block you have to declare the database, you want to delete from, in the XML - configuration file. VAR_INPUT VAR_INPUT sNetID : T_AmsNetId; hDBID : UDINT; cbCmdSize : UDINT; pCmdAddr : UDINT; bExecute : BOOL; tTimeout : TIME; END_VAR sNetID : Is a string containing the AMS network identifier of the target device to which the ADS command is directed. hDBID : Indicates the ID of the database to be used.
cbCmdSize : Indicates the length of the INSERT command. pCmdAddr : Pointer to the executed INSERT command. bExecute : The command is executed with the rising edge. tTimeout : States the time before the function is cancelled. TS6420 74 Version:
1.2 Logging of values from an ADS-device (not for BC9000) Logging of values from a BC9000 FB DBWrite1( _ sNetID:= , hDBID:= 1, hAdsID:= 1, sVarName:= 'MAIN.TestVar', sDBVarName:= 'DBTestVar', eDBWriteMode:= eDBWriteMode Append, _ bExecute:= TRUE, tTimeout:= T#15s, bBusy=> busy, bError=> err, nErrID=> errid, sSQLState=> sqlstate ); FB DBWrite1( _ sNetID:= , hDBID:= 1, hAdsID:= 1, sVarName:= 'MAIN.TestVar', nIGroup:= 16448, nIOffset:= 0, nVarSize:= 16, sVarType:= 'REAL', sDBVarName:= 'DBTestVar', eDBWriteMode:= eDBWriteMode Append, _ bExecute:= TRUE, tTimeout:= T#15s, bBusy=> busy, bError=> err, nErrID=> errid, sSQLState=> sqlstate ); Development environment Target system type PLC libraries to be linked TwinCAT v2.10.0 PC or CX (x86) TcDatabase.Lib TwinCAT v2.10.0 CX (ARM)