PLC API VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; bError : BOOL; nErrID : UDINT; sSQLState : ST_DBSQLError; END_VAR bBusy : The command is in the process of being transmitted by ADS. No new command will be accepted if "bBusy" remains TRUE. bError : Becomes TRUE, as soon as an error occurs. nErrID : Supplies the ADS Error Code [ } 132] or the TcDatabaseSrv_Error_Codes [ } 135] when the bError output is set. sSQLState : Supplies the SQL error code [ } 89] of the specified database type. Requirements 7.1.17 FB_DBRecordArraySelect The FB_DBRecordArraySelect allows some individual data records to be read from a database. The length of the SQL-command could be till 10000 Symbols.
This function block is not compatible with ASCII files. VAR_INPUT VAR_INPUT sNetID : T_AmsNetID; hDBID : UDINT; cbCmdSize : UDINT; pCmdAddr : UDINT; nStartIndex : UDINT; nRecordCount : UDINT; cbRecordArraySize : UDINT; pDestAddr : DWORD; bExecute : BOOL; tTimeout : TIME; END_VAR sNetID : Is a string containing the AMS network identifier of the target device to which the ADS command is directed. hDBID : Indicates the ID of the database to be used. cbCmdSize : Indicates the size of the SELECT command. TS6420 76 Version: 1.2 Development environment Target system type PLC libraries to be linked TwinCAT v2.10.0 PC or CX (x86) TcDatabase.Lib TwinCAT v2.10.0 CX (ARM)