beckhoff TS6420 — 7.1.20.4 FB_DBRecordSelect_EX

PLC API 7.1.20.4 FB_DBRecordSelect_EX The FB_DBRecordSelect_EX allows individual data records to be read from a database. The length of the SQL-command could be till 10000 Symbols. This function block is not compatible with ASCII files. VAR_INPUT VAR_INPUT sNetID : T_AmsNetID; hDBID : UDINT; cbCmdSize : UDINT; pCmdAddr : UDINT; nRecordIndex : UDINT; cbRecordSize : UDINT; pDestAddr : DWORD; bExecute : BOOL; tTimeout : TIME; END_VAR sNetID : Is a string containing the AMS network identifier of the target device to which the ADS command is directed. hDBID : Indicates the ID of the database to be used. cbCmdSize : Indicates the size of the SELECT command. pCmdAddr :

Pointer to the executed SELECT command. nRecordIndex : Gives the index of the data record that is to be read. cbRecordSize : Provides the size of a data record in bytes. pDestAddr : Provides the address of the structure into which the data record is to be written. bExecute : The command is executed with the rising edge. tTimeout : States the time before the function is cancelled. VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; bError : BOOL; nErrID : UDINT; sSQLState : ST_DBSQLError; nRecords : UDINT; END_VAR bBusy : The command is in the process of being transmitted by ADS. No new command will be accepted if "bBusy" remains TRUE. bError : Becomes TRUE, as soon as an error occurs. TS6420 85 Version: 1.2