Delta Electronics — More About P2-26

• The PI + Feed-Forward is more responsive where the PDF has better ability to resist disturbance. • This is from the view of Speed Loop , and you should integrate the response with the 3 cascaded loops. • By adjusting P2-26, the system can be tuned as PI + Feed-Forward or PDF. • ASDA Series employs a famous control skeleton called PDFF. Pseudo-Derivative Feedback with Feed-Forward More About P2-26