Beckhoff Automation GmbH & Co. KG TwinCAT 2 | ADS-Script-DLL — 4.2 Reading and writing of PLC variables

Examples Visual Basic 6 program Option Explicit Public TcClientSync As TCSCRIPTLib.TcScriptSync Public nAdsAmsPort As Integer Public strAdsAmsNetId As String Private Sub Form_Load() Set TcClientSync = CreateObject("TcScript.TcScriptSync") Call TcClientSync.ConnectTo("", 801) End Sub Private Sub Form_Terminate() Set TcClientSync = Nothing End Sub Private Sub cmdConnect_Click() nAdsAmsPort = CLng(txtAdsAmsPort.Text) if (Len(txtAdsAmsNetId.Text) > 0) Then strAdsAmsNetId = txtAdsAmsNetId.Text Else strAdsAmsNetId = "" End If Set TcClientSync = CreateObject("TcScript.TcScriptSync") Call TcClientSync.ConnectTo(strAdsAmsNetId, nAdsAmsPort) End Sub Private Sub cmdRead_Click() Dim VarBool As Variant Dim VarInt8 As Byte Dim VarInt16 As Integer Dim VarInt32 As Long Dim VarReal32 As Single Dim VarReal64 As Double VarBool = TcClientSync.ReadBool(&H4020, 0) lblBoolean.Caption = VarBool TX1000 31 Version:

1.0