beckhoff TwinCAT 2 PLC Control — 4.2 Options

Individual Components Editor If you choose this category, then you get the following dialog box: When activating an option, a check (ь) appears before the option. You can make the following settings for the Editors: Autodeclaration Autoformat List components Declaration as tables Tab width Font Display of the text selection (Mark) Display of the Bitvalues Suppress monitoring of complex types (array, pointer, VAR_IN_OUT) Show POU symbols Autodeclaration If you have chosen the Autodeclaration, then (following the input of a not-yet-declared variable) a dialog box will appear in all editors with which this variable can be declared.

Autoformat If the option Autoformat in the category Editor of the options dialog box has been chosen, then TwinCAT PLC Control executes automatic formatting in the IL editor and in the declaration editor. When you finish with a line, the following formatting is made: Operators written in small letters are shown in capitals; Tabs are inserted to that the columns are uniformly divided. List components: TwinCAT 2 PLC Control 47 Version: 1.0