beckhoff TwinCAT 2 PLC Control — 4.3 Managing Projects

Individual Components In addition, with "Insert" "Bitmap" you can insert a bitmap graphic (e.g. a company logo) in the page. After selecting the graphic, a rectangle should also be drawn here on the layout using the mouse. If the template was changed, then TwinCAT PLC Control asks when the window is closed if these changes should be saved or not. 'File' 'Exit' Shortcut: + With this command you exit from TwinCAT PLC Control. If a project is opened, then it is closed as described in "File" "Save". Possible Actions with Projects: 'Project' 'Build' + The project is compiled using 'Project' 'Build' . The compilation process is basically incremental, that is only changed POUs are recompiled.

A non-incremental compilation can also be obtained if the command 'Project' 'Clear all' is first executed. For target systems that support Online Change, all POUs that will be loaded into the controller on the next download are marked with a blue arrow in the Object Organizer after compilation. The compilation process that is carried out with ' Project' 'Build' occurs automatically if the controller is logged-in via 'Online' 'Log-in'. During compilation a message window is opened which shows the progress of the compilation process and any errors and warnings which may occur during compilation. Errors and warnings are marked with numbers.

Using F1 you get more information about the currently selected error. A list of all error messages [ } 265] is to be found in the appendix. If the option Save before compilation is selected in the options dialog of the Load & Save category, the project is stored before compilation. NOTE Cross references are created during compilation and are stored with the compilation information. In order to be able to use the commands 'Show Call Tree' , ' Show Cross Reference ' and the commands 'Unused Variables ', ' Concurrent Access' , and ' Multiple Write Access on output ' in the 'Project' 'Check' menu, the project must be rebuilt after any change.

‘Project’ ’Rebuild all’ With 'Project' 'Rebuild all' , unlike the incremental compilation ( 'Project' 'Build' ), the project is completely recompiled. Download-Information is not discarded, however, as is the case with the command 'Clear All' . TwinCAT 2 PLC Control 74 Version: 1.0 Command Placeholder Description Page {Page} Here the current page number appears in the printout. POU name {POUName} Here the current name of the POU appears. File name {FileName} Here the name of the project appears. Date {Date} Here the current date appears. Contents {Content} Here the contents of the POU appears.