Reference | I/O Devices 0x02 = Data Exchange Active (0 = No data exchange) 0x04 = PCP Communication Established (0 = No PCP communication) 0x08 = Initialization Error Detected (0 = No initialization fault) 0x10 = Runtime Error Detected (0 = No runtime error) 0x20 = Application is in 'NotReady' State (0 = System running) Via these flags the slave application can detect the state of the InterBus (master). During data exchange with the master, the bits Bus Active and Data Exchange Active are set. If the master is not configured, the bit Application is in 'NotReady' State may be set. LengthCode : Shows the current length code of the slave module. Default:
21 ( = 10 words input and output process data length). IdentCode : Shows the current ID code of the slave module. Default: Digital I/O slave ( ID code = 0x03 ). ErrorCounter : Number of errors detected since the module was switched on. EventError : Error code of the last detected error. See CIF50-IBS error codes [ } 161] . AddParam : Additional error code parameters (optional). See CIF50-IBS error codes [ } 161] . CIF50-IBS slave data (slave process data) The length of the process data can be configured via the "Slave Data" context menu. "Slave Data" context menu Right-clicking on "Slave Data" in the configuration tree brings up the following menu: TwinCAT 2 159 Version: 1.7